Exposure - Shoulder

From wikiRadiography
Jump to navigation Jump to search
This page contains radiographic exposure values

Adult Shoulder

Region View kVp mAs Cassette Grid Distance
Shoulder AP - External Rotation 65 16 Standard Yes 100 - 115cm (40 inches)

AP - Neutral Rotation 65 16 Standard Yes 100 - 115cm (40 inches)

AP - Internal Rotation 65 16 Standard Yes 100 - 115cm (40 inches)

Glenohumeral (GH) 65 16 Standard Yes 100 - 115cm (40 inches)

Lateral (Y) 70 20 Standard Yes 100 - 115cm (40 inches)

Lateral (Neers) 75 25 Standard Yes 100 - 115cm (40 inches)

Lateral Transthoracic 80 50 Standard Yes 100 - 115cm (40 inches)

Superoinferior (SI) 55 8 Detail No 100 - 115cm (40 inches)

Inferosuperior (IS)558DetailNo 100 - 115cm (40 inches)


Paediatric Shoulder

Region View kVp mAs Cassette Grid Distance
Shoulder AP - External Rotation 60 12 Standard Yes 100 - 115cm (40 inches)

Lateral (Y) 65 16 Standard Yes 100 - 115cm (40 inches)

Superoinferior (SI) 50 6 Detail No 100 - 115cm (40 inches)


These are average exposures using a Carestream CR system, exposures may vary dramatically between different film/screen combinations, CR or DR systems


Exposure Chart....Go Back to Exposure Values homepage