Exposure - Toes

From wikiRadiography
Jump to navigation Jump to search
This page contains radiographic exposure values

Adult Toes

Region View kVp mAs Cassette Grid Distance
ToesDP552.5DetailNo100 - 115cm (40 inches)

Oblique552.5DetailNo100 - 115cm (40 inches)

Lateral552.5DetailNo100 - 115cm (40 inches)

Axial (Sesamoids)502DetailNo100 - 115cm (40 inches)

Paediatric Toes

Region View kVp mAs Cassette Grid Distance
ToesDP502DetailNo100 - 115cm (40 inches)

Oblique502DetailNo100 - 115cm (40 inches)

Lateral502DetailNo100 - 115cm (40 inches)


These are average exposures using a Carestream CR system, exposures may vary dramatically between different film/screen combinations, CR or DR systems

Exposure Chart....Go Back to Exposure Values homepage


Toes Links
Toes Positioning
Toes Radiographic Anatomy