Exposure - Sternum

From wikiRadiography
Jump to navigation Jump to search
This page contains radiographic exposure values

Adult Sternum

Region View kVp mAs Cassette Grid Distance
SternumRight Anterior Oblique7525 x 3 secondsRegularYes100 - 115cm (40 inches)

Lateral 7525 RegularYes100 - 115cm (40 inches)

Paediatric Sternum

Region View kVp mAs Cassette Grid Distance
SternumRight Anterior Oblique7018 x 3 secondsRegularYes100 - 115cm (40 inches)

Lateral 7018 RegularYes100 - 115cm (40 inches)


These are average exposures using a Carestream CR system, exposures may vary dramatically between different film/screen combinations, CR or DR systems

Exposure Chart....Go Back to Exposure Values homepage