Exposure - Hand

From wikiRadiography
Jump to navigation Jump to search
This page contains radiographic exposure values

Adult Hand

Region View kVp mAs Cassette Grid Distance
HandPA502.5DetailNo100 - 115cm (40 inches)

Oblique522.5DetailNo100 - 115cm (40 inches)

Lateral543.2DetailNo100 - 115cm (40 inches)

Fan Lateral543.2DetailNo100 - 115cm (40 inches)

Ballcatchers502.5DetailNo100 - 115cm (40 inches)

Paediatric Hand

Region View kVp mAs Cassette Grid Distance
HandPA482DetailNo100 - 115cm (40 inches)

Oblique502DetailNo100 - 115cm (40 inches)

Boneage Assessment482DetailNo100 - 115cm (40 inches)


These are average exposures using a Carestream CR system, exposures may vary dramatically between different film/screen combinations, CR or DR systems

Exposure Chart....Go Back to Exposure Values homepage