This page contains radiographic exposure values

Adult Temporal Bones / Petrous Pyramids

Region View kVp mAs Cassette Grid Distance
Temporal BonesTownes8020RegularYes100 - 115cm (40 inches)

Submentovertex (SMV)7018RegularYes100 - 115cm (40 inches)

PaediatricTemporal Bones / Petrous Pyramids

Region View kVp mAs Cassette Grid Distance
Temporal BonesTownes7016RegularYes100 - 115cm (40 inches)

Submentovertex (SMV)6812RegularYes100 - 115cm (40 inches)